Service |
Price |
Person in Charge |
Lyophilization of liquid samples |
132 BGN/24 hours |
Assoc. Prof. Eli Grigorova; |
Mechanochemical synthesis, amorphization of solid materials, homogenization and milling in high energy mills |
|
|
- Ball milling in air for 1 h |
30 BGN |
Assoc. Prof. Eli Grigorova; |
- For every additional hour |
25 BGN |
Assoc. Prof. Eli Grigorova; |
- Ball milling in different than air media (if the gas is not available, it should be paid for its delivery, bottle and rent) |
38 BGN |
Assoc. Prof. Eli Grigorova; |
Dehydration under vacuum |
60 BGN/ hour |
Assoc. Prof. Eli Grigorova; |
Solid phase synthesis in oxidation or reduction media in a specified temperature range |
70 BGN/ hour |
Assoc. Prof. Eli Grigorova; |
Preparation of carbon dioxide gas-diffusion electrode |
48BGN/ hour |
Dr. Blagoy Burdin; |
Preparation of a carbon free gas-diffusion electrode |
65BGN/ hour |
Dr. Blagoy Burdin; |
Service |
Price |
Person in Charge |
Galvanostatic tests – Current range from 1.0х10-5 to 3.0 А and voltage range 0-5 V. Rate capability tests of single electrodes and commercial cells. |
10 BGN/ hour |
Dr. Simeon Stankov; |
Potentiodynamic tests – voltage range: 1.0х10-2 – 5.0 V. |
10 BGN/ hour |
Dr. Simeon Stankov; |
Constant Current-Constant Voltage (CCCV) charge mode. |
20 BGN/ hour |
Dr.Simeon Stankov; |
Discharge at Constant Resistance (CR) – 1.6 – 1х105 Ω
|
10 BGN/ hour |
Dr.Simeon Stankov; |
Electrochemical titration – V/x relation plot.
|
20 BGN/ hour |
Dr. Simeon Stankov; |
DV/dx relation plot.
|
40 BGN/ hour |
Dr.Simeon Stankov; |
Cyclic Voltammetry (CV) – scan rate: 0.01 - 100 mV sec-1 |
40 BGN/ hour |
Dr. Simeon Stankov; |
Electrochemical tests at low temperature: min T= -40°С |
80 BGN/ hour |
Dr. Simeon Stankov; |
Electrochemical Impedance Spectroscopy in frequency range 3х10-5 – 1х106 Hz |
60 BGN/ hour |
Dr. Simeon Stankov; |
Processing, plotting and interpretation of the obtained results |
Under negotiation |
Dr. Simeon Stankov; |
Development of specific test procedures at the customer request.
|
Under negotiation |
Dr. Simeon Stankov; |
Electrochemical Impedance Spectroscopy at room temperature |
100 BGN/ hour |
Dr. Blagoy Burdin; |
Potentiostatic battery tests in a range of voltages up to ± 4.0V, (at minimum 2 hours) |
26 BGN/ hour |
Dr. Blagoy Burdin; |
Galvanostatic battery tests – current range ± 5.0А |
|
|
- Testing of of half cells |
26 BGN/ hour |
Dr. Blagoy Burdin; |
- Testing of full cell configuration |
26 BGN/ hour |
Dr. Blagoy Burdin; |
- Commercial cells/batteries |
26 BGN/ hour |
Dr. Blagoy Burdin; |
Charge / discharge tests in galvanostatic-potentiostatic mode |
15 BGN/ hour |
Dr. Blagoy Burdin; |
Charge / discharge tests in galvanostatic-potentiostatic mode combined with impedance measurements |
40 BGN/ hour |
Dr. Blagoy Burdin; |
Current-voltage characteristic |
10 BGN/ hour |
Dr. Blagoy Burdin; |
Current-voltage characteristic combined with impedance measurements |
30 BGN/ hour |
Dr. Blagoy Burdin; |
Differential Coulometric Spectroscopy |
Under negotiation |
Dr. Blagoy Burdin; |
Service |
Price |
Person in Charge: |
Thermal analysis |
100 BGN/hour |
Assoc. Prof. Eli Grigorova ; |
Thermal analysis with gas phase analysis by mass spectrometry |
120 BGN /hour |
Assoc. Prof. Eli Grigorova ; |
X-Ray Phase Analysis |
|
|
- Diffractogram |
40 BGN |
Assoc. Prof. Eli Grigorova ; |
- Phase identification (up to two phases) |
20 BGN |
Assoc. Prof. Eli Grigorova ; |
- Phase identification (over two phases - for each additional) |
10 BGN |
Assoc. Prof. Eli Grigorova ; |
- Quantitative Phase Analysis |
240 BGN |
Assoc. Prof. Eli Grigorova ; |
- Determination of the size of crystallites and micro stresses |
100 BGN |
Assoc. Prof. Eli Grigorova ; |
- Determination of cell parameters (for 1 phase) |
200 BGN |
Assoc. Prof. Eli Grigorova ; |
- Determining the average thickness of the polycrystalline coating |
100 BGN |
Assoc. Prof. Eli Grigorova ; |
- Precise Phase Indexing |
200 BGN |
Assoc. Prof. Eli Grigorova ; |
- Software processing of digital powder diffractograms |
Under negotiation |
Assoc. Prof. Eli Grigorova ; |
- Determination of crystalline phase structure in polycrystalline materials |
Under negotiation |
Assoc. Prof. Eli Grigorova ; |
Electronic microscope: Operating |
120 BGN/hour |
Assoc. Prof. Eli Grigorova ; |
- Sample preparation |
30 BGN |
Assoc. Prof. Eli Grigorova ; |
- Interpretation of TEM results |
Under negotiation |
Assoc. Prof. Eli Grigorova ; |
- Determination of specific BET surface |
35 BGN |
Assoc. Prof. Eli Grigorova ; |
- Full adsorption isotherm with mesopores size distribution |
70 BGN |
Assoc. Prof. Eli Grigorova ; |
- Full adsorption isotherm with micropores and mesopores size distribution |
80 BGN |
Assoc. Prof. Eli Grigorova ; |
The electrical conductivity measurements of solid samples over a wide temperature range |
|
|
- Determination of the electrical properties of solids |
40 BGN /sample |
Assoc. Prof. Eli Grigorova ; |
- Determination of the electrical properties of solids in the temperature range 100 - 600 K |
200 BGN /sample |
Assoc. Prof. Eli Grigorova ; |
Analysis by Electronic Paramagnetic Resonance Spectrometer X- range, 9.4GHz) |
|
|
- Full Temperature Range (70 - 450 K) |
150 BGN |
Assoc. Prof. Eli Grigorova ; |
- Room temperature (300 K) |
25 BGN |
Assoc. Prof. Eli Grigorova ; |
- Temperature of liquid nitrogen and room temperature |
40 BGN |
Assoc. Prof. Eli Grigorova ; |
- Quantitative EPR |
46 BGN |
Assoc. Prof. Eli Grigorova ; |
Анализ чрез Електронен парамагнитен резонансен спектрометър (Q- range, 35 GHz) |
150 BGN |
Assoc. Prof. Eli Grigorova ; |
- Full Temperature Range (70 - 450 K) |
Q-обхват, 35 GHz |
Assoc. Prof. Eli Grigorova ; |
- Room temperature (300 K) |
180 BGN |
Assoc. Prof. Eli Grigorova ; |
- Temperature of liquid nitrogen and room temperature |
30 BGN |
Assoc. Prof. Eli Grigorova ; |
- Quantitative EPR |
50 BGN |
Assoc. Prof. Eli Grigorova ; |
X-Ray Photoelectron spectroscopy |
55 BGN |
Assoc. Prof. Eli Grigorova ; |
- Analysis of one surface of a solid sample |
150 BGN |
Assoc. Prof. Eli Grigorova ; |
- Profile in depth |
100 BGN на точка от профила |
Assoc. Prof. Eli Grigorova ; |
- Interpretation of the received spectra |
Under negotiation |
Assoc. Prof. Eli Grigorova ; |
Inductively coupled plasma atomic emission spectroscopy |
|
|
- Determination of metal ions in solution |
5.00- 20.00 BGN/ sample |
Assoc. Prof. Eli Grigorova ; |
- Elaboration of methodologies and scientific interpretation |
Under negotiation |
Assoc. Prof. Eli Grigorova ; |
Flame atomic absorption spectroscopy* |
|
|
- Analysis of metal ions in solution / analysis of metal ions in solution |
15.00 - 40.00 BGN / sample |
Assoc. Prof. Eli Grigorova ; |
- Elaboration of methodologies and scientific interpretation |
Under negotiation |
Assoc. Prof. Eli Grigorova ; |
* The prices are for analyses in solution |
|
|
Infrared Spectrometer analysis |
|
|
- IR spectrum of a powder - in a tablet of KBr |
18 BGN |
Assoc. Prof. Eli Grigorova ; |
- IR spectrum of powder – with made tablet of KBr |
10 BGN |
Assoc. Prof. Eli Grigorova ; |
- Determination of surface proton acidity of oxide materials and zeolites by |
350.00 BGN /sample |
Assoc. Prof. Eli Grigorova ; |
- Interpretation of IR results |
Under negotiation |
Assoc. Prof. Eli Grigorova ; |
X-ray diffraction analysis (XRD) |
50 BGN/sample |
Prof. Sasho Vasilev; |
Hg porometry |
100 BGN/sample |
Prof. Sasho Vasilev; |
Scanning Electron Microscopy (SEM) |
100 BGN/sample |
Prof. Sasho Vasilev; |
BET analysis |
50 BGN/sample |
Prof. Sasho Vasilev; |
Pore analysis in capillary flow |
50 BGN/sample |
Prof. Sasho Vasilev; |
Gas permeability |
50 BGN/sample |
Prof. Sasho Vasilev; |
DTA / TG / DSC analysis |
60 BGN/sample |
Prof. Sasho Vasilev; |
Gas permeability measurement of porous materials with different gases: hydrogen, air, oxygen, nitrogen, argon and gas mixtures, sample size up to φ=45mm. |
18 BGN/ hour |
Dr. Blagoy Burdin; |